기후변화 및 폭염대응 증발냉각시스템 적용에 따른 내·외부 열환경 변화 연구
Thermal Environment Transition of Response Climate Change and Heat Wave Application Evaporative Cooling System
김정호 ( Jeong-ho Kim ) , 김학기 ( Hak-gi Kim ) , 윤용한 ( Yong-han Yoon ) , 권기욱 ( Ki-uk Kwon )
UCI I410-ECN-0102-2017-400-000551990
* 발행 기관의 요청으로 이용이 불가한 자료입니다.

This study evaporative cooling system a heat wave climate change and reduction of the inside and outside thermal environment change research. Measurement items included micro meteorological phenomena and measured comfort indices. A micro meteorograph of temperature, relative humidity, surface temperature, and the comfort indices of WBGT, UTCI, and PMV were measured. The difference in inside and outside temperatures were compared for different land types, with the largest difference found in Type A (4.81℃), followed by Type B (4.40℃ ) and Type C (3.12℃). Relative humidity was about 10.43% higher inside due to water injection by the evaporative cooling system. Surface temperature was inside about 6.60℃ higher than the outside all types. WBGT were Type A (3.50℃) > Type B (2.71℃) > Type C (1.88℃). UTCI was low heat stress inside than outside all types. PMV was analysed Type C for inside predicted percentage of dissatisfied 75%, other types was percentage of dissatisfied 100% by inside and outside. Correlation analysis between land cover type and temperature, surface temperature, pmv, utci. T-test analysed inside and outside temperature difference was significant in all types of land.